From Wiki Knowledge Base | Teltonika Mobility
|
CAUTION! Both firmwares (Modem and BlueNRG) must be flashed into device. Failing so can lead to unexpected device behavior and rapid battery discharge.
|
TAT100 BlueNRG & Modem FIRMWARE UPDATE GUIDE
Download Firmware and Configurator from STABLE FIRMWARE or SHORT-TERM FIRMWARE pages.
After device connection to Configurator:
1) Select Update firmware;
2) Select to flash Firmware(*.e.XIM) file;
3) Click on file;
4) And select Open.
Wait until the device will upload the firmware.
When parameters successfully loaded:
1) Select Update firmware;
2) Select to flash BlueNRG firmware(*.bin);
3) Click on file;
4) And select Open.
|
STABLE FIRMWARE
|
FIRMWARE VERSION:
|
55.00.16.Rev.522
|
CONFIGURATOR VERSION:
|
1.7.16_R.TAT100.R2
|
BlueNRG VERSION:
|
10.2.21.Rev.01
|
RELEASE DATE:
|
2021.12.21
|
TAT100 Hardware version identification
|
- If Serial Number [S/N] is greater than 1122473261, then device version: TAT100 HW: 62.
- If Serial Number [S/N] is less than 1122473261, then device version: TAT100 HW: 31.
|
ORDERS AFTER 2022-03-17 WILL BE WITH TAT100 HARDWARE: 62
|
CAUTION!
|
When updating firmware via FOTA WEB, pay attention to notice above.
|
|
|
CHANGELOG
|
VERSION
|
RELEASE DATE
|
CONFIGURATOR CHANGES
|
FIRMWARE CHANGES
|
Firmware version: 55.00.16.Rev.522 BlueNRG version: 10.2.21.Rev.01 Configurator version: 1.7.16_R.TAT100.R2
|
2021.12.21
|
|
- Improved battery safety features
- Fixed stuck download during FOTA update
- Fixed device not restarting to update FW after FOTA download
- Improved main device packet filtering
- Improved battery voltage measurement
- Fixed the device not restarting after FOTA WEB update when it happens at the same time as periodic record
- Fixed random statistic losses
- Fixed GNSS module status not being accurate in Teltonika Configurator
- Improved static navigation mode
- Fixed scheduler time resync timer not working properly
- Fixed statistic not being deleted from RAM
|
VERSION
|
RELEASE DATE
|
CONFIGURATOR CHANGES
|
FIRMWARE CHANGES
|
Firmware version: 55.00.15.Rev.519 BlueNRG version: 10.2.14 Configurator version: 1.7.16_R.TAT100.R2
|
2021.10.19
|
|
- Fixed fake movement detection on startup
- Fixed problem when the device is stuck in On Stop tracking mode after reconfiguration
- Added Power-On reason data and fixed version changes to device statistics
- Fixed Backup tracker issue where the alarm mode is not immediately activated when the central device disappears
- Fixed empty GSM I/O elements
- Fixed an issue where UTC is added after each reconfiguration
- Added record printing to
Dump log
- LBS data is not included in records if GNSS fix was caught
- Fixed NTP timesync failure if offset is zero
- Improved record creation (wake up from sleep) during Backup tracker alarms
- Improved GNSS module control with
Static Navigation and LBS
- Added prevention from inappropriate record generation if the battery is low (HW watchdog)
- Added statistic element for USB connected uptime
- Added timestamp to BlueNRG serial prints
- Minor improvement for BlueNRG firmware update via configurator
- Added filter for
LBS cell_id duplicates
- Improved Bluetooth sensor record creation with
'On Change' operand
- Added Bluetooth sensor support
- Added condition to skip LBS data update if location source is only GNSS
- Increased retries of AT+# command in order to avoid empty LBS data from modem
- Changed
Open link timeout to 15s
- Fixed an issue where the tracking mode would change from the scheduler to periodic
- Improved logic for multiple
FOTA Web tasks update in the same connection
- Implemented rule for additional connection to
FOTA Web after baseband firmware update
- Added accelerometer version information inside '.info' serial command
- Fixed an issue with battery voltage
I/O element when record saving is overlapping with a firmware update
- Fixed
Scheduler record sending at midnight
- Fixed missed LBS values inside
I/O elements
- Fixed an issue when GNSS speed is not zero while the device is in a stationary position
- General minor improvements
|
55.00.10.Rev.509 BlueNRG: 10.2.3_Rev.00 1.7.16_E.TAT100_04
|
2021.05.10
|
- Added
Test Connection button
- Temporarily removed
Secondary Server Settings
- Tracking Period default value changed to 28800 (s)
|
- Implemented
Test Connection feature.
- Added BlueNRG logging to DUMP files
- Added LBS data logging to DUMP files
- Added protection that blocks FMB firmware flash to AT devices
- Added time-sync update with asset purpose command
- Improved periodic record timer logic
- Improved battery voltage measurement
- Improved periodic GPRS data sending while USB is connected to the device
- Disabled SMPS filter
- Fixed record sending when movement is triggered at all times
- Improved NTP time-sync
|
55.00.05.Rev.510 BlueNRG: 0.1.7
|
2020.12.03
|
- Removed tracking scenarios
- Removed speed source parameter
- Removed record saving/sending without TS parameter
- Removed LED Indication parameter
- Removed NTP resync parameter
|
- Implemented FOTA support.
- Improved GNSS position capturing.
- Reworked Periodic and Scheduler tracking counters.
- Implemented device logging via USB.
- Implemented statistics acquisition to flash memory.
|
55.00.05.Rev.507 BlueNRG: 0.1.5
|
2020.09.29
|
- Implemented GNSS Source configuration. Available options: BeiDou, GLONASS, Galileo and GPS.
- Added I/O elements: Data Mode, GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, Speed, GSM Cell ID, GSM Area Code, Battery Voltage, Active GSM Operator, ICCID, Coordinates ISO6709.
- Added SMS command autorization via Login and Password logic.
|
- Implemented 'Codec 8', 'Codec 8 Extended' and 'Codec 12' protocols.
- Implemented NTP, NITZ and GNSS time synchronization sources.
- Implemented ability to send GPRS data from device via TCP or UDP channels.
- Implemented connection to server timeouts.
- Ported TLS encryption functionality from other Teltonika devices.
- Implemented Periodic and Scheduler tracking.
- Implemented BlueNRG firmware update via GPRS. This function will be used to reflash BlueNRG firmware via FOTA WEB.
- Added GSM number authorization logic.
|
|