Template:SAS device Parameter list - Communication modifications no 1

From Wiki Knowledge Base | Teltonika Mobility

Communication modifications

UART

Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
150 Uint16 0 0 1 0 – Disable External UART Mode
1 – UART

UART Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
151 Uint16 0 0 6 0 – Log Mode Eventual Records
1 – NMEA
2 – TCP Ascii
3 – TCP Binary
4 – TCP Ascii Buffered
5 – TCP Binary Buffered
6 – e-floater

UART Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
153 Uint16 1 0 1 0 – Default Eventual Records (Parity)
1 – None
2 – Odd
3 – Even
152 Uint16 1 0 1 0 – Default Baudrate
1 – 9600
2 – 14400
3 – 19200
4 – 38400
5 – 57600
6 – 115200
158 Uint16 0 0 1 0 – Disable Message Timestamp
1 – Enable

TCP Binary Mode Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
154 Uint8 0 0 255 - Prefix 1
155 Uint8 0 0 255 - Prefix 2
156 Uint8 0 0 255 - Prefix 3

E-Scooter I/O

Parameter ID Parameter Type Default value Value range Value Parameter name Input name
Min Max
51310 Uint8 0 0 3 0 – None Priority State of health
1 – Low
2 – High
3 – Panic
51313 Uint8 0 0 100 % Low Level
51312 Uint8 0 0 100 % High Level
51314 Uint8 0 0 2 0 – No Event Only
1 – Yes
51311 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7334 Uint8 0 0 10 Predefined Number Send SMS To
8334 String State of health 0 160 Predefined Number SMS Text
51400 Uint8 0 0 3 0 – None Priority Battery percentage
1 – Low
2 – High
3 – Panic
51403 Uint8 0 0 100 % Low Level
51402 Uint8 0 0 100 % High Level
51404 Uint8 0 0 2 0 – No Event Only
1 – Yes
51401 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7343 Uint8 0 0 10 Predefined Number Send SMS To
8334 String Battery percentage 0 160 Predefined Number SMS Text
51510 Uint8 0 0 3 0 – None Priority Battery temperature
1 – Low
2 – High
3 – Panic
51513 Uint8 0 0 65535 °Cx10 Low Level
51512 Uint8 0 0 65535 °Cx10 High Level
51514 Uint8 0 0 2 0 – No Event Only
1 – Yes
51511 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7354 Uint8 0 0 10 Predefined Number Send SMS To
8354 String Battery temperature 0 160 Predefined Number SMS Text
51560 Uint8 0 0 3 0 – None Priority Charge capacity
1 – Low
2 – High
3 – Panic
51563 Uint8 0 0 65535 mAh Low Level
51562 Uint8 0 0 65535 mAh High Level
51564 Uint8 0 0 2 0 – No Event Only
1 – Yes
51561 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7359 Uint8 0 0 10 Predefined Number Send SMS To
8359 String Charge capacity 0 160 Predefined Number SMS Text
51610 Uint8 0 0 3 0 – None Priority Charge cycles
1 – Low
2 – High
3 – Panic
51613 Uint8 0 0 65535 - Low Level
51612 Uint8 0 0 65535 - High Level
51614 Uint8 0 0 2 0 – No Event Only
1 – Yes
51611 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7364 Uint8 0 0 10 Predefined Number Send SMS To
8364 String Charge cycles 0 160 Predefined Number SMS Text
51640 Uint8 0 0 3 0 – None Priority Battery serial number
1 – Low
2 – High
3 – Panic
51644 Uint8 0 0 2 0 – No Event Only
1 – Yes
51641 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7367 Uint8 0 0 10 Predefined Number Send SMS To
8367 String Battery serial number 0 160 Predefined Number SMS Text
52670 Uint8 0 0 3 0 – None Priority Activity status
1 – Low
2 – High
3 – Panic
52673 Uint8 0 0 3 - Low Level
52672 Uint8 0 0 3 - High Level
52674 Uint8 0 0 2 0 – No Event Only
1 – Yes
52671 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7470 Uint8 0 0 10 Predefined Number Send SMS To
8470 String Activity status 0 160 Predefined Number SMS Text

RS232

Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
150 Uint16 0 0 1 0 – Disable External UART Mode
1 – RS232

RS232 Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
151 Uint16 0 0 5 0 – Log Mode Eventual Records
1 – NMEA
2 – TCP Ascii
3 – TCP Binary
4 – TCP Ascii Buffered
5 – TCP Binary Buffered

RS232 Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
153 Uint16 1 0 1 0 – Default Eventual Records (Parity)
1 – None
2 – Odd
3 – Even
152 Uint16 1 0 1 0 – Default Baudrate
1 – 9600
2 – 14400
3 – 19200
4 – 38400
5 – 57600
6 – 115200
158 Uint16 0 0 1 0 – Disable Message Timestamp
1 – Enable

TCP Binary Mode Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
154 Uint8 0 0 255 - Prefix 1
155 Uint8 0 0 255 - Prefix 2
156 Uint8 0 0 255 - Prefix 3

CAN

CAN protocol

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
250 Uint16 0 0 24 0 – None External UART Mode
1 – Bosch
2 – Askoll
3 – Default J1939
4 – Manual CAN
5 – Manual J1939
6 – FLEX
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
319 Uint8 85 0 255 Number J1939 Source Address J1939 Settings
320 Uint8 0F00FFF8FFF7876E 16 16 Symbols J1939 Name
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
302 Uint16 1 0 1 0 - Disable 120Ohm Termination Resistor
1 – Enable

CAN I/O

Parameter ID Parameter Type Default value Value range Value Parameter name Input name CAN protocol
Min Max
51780 Uint8 0 0 3 0 – None Priority Park Brake Bosch
1 – Low
2 – High
3 – Panic
50183 Uint8 0 0 3 - Low Level
51782 Uint8 0 0 3 - High Level
51784 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51781 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7381 Uint8 0 0 10 Predefined Number Send SMS To
8381 String Park Brake 0 160 Predefined Number SMS Text
51790 Uint8 0 0 3 0 – None Priority Selected Charge mode Bosch
1 – Low
2 – High
3 – Panic
51793 Uint8 0 0 3 - Low Level
51792 Uint8 0 0 3 - High Level
51794 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51791 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7382 Uint8 0 0 10 Predefined Number Send SMS To
8382 String Selected Charge Mode 0 160 Predefined Number SMS Text
51800 Uint8 0 0 3 0 – None Priority Charger State Bosch
1 – Low
2 – High
3 – Panic
51803 Uint8 0 0 255 - Low Level
51802 Uint8 0 0 255 - High Level
51804 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51801 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7383 Uint8 0 0 10 Predefined Number Send SMS To
8383 String Charger State 0 160 Predefined Number SMS Text
51810 Uint8 0 0 3 0 – None Priority Charger Voltage Bosch/Askoll
1 – Low
2 – High
3 – Panic
51813 Uint8 0 0 65535 mV Low Level
51812 Uint8 0 0 65535 mV High Level
51814 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51811 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7384 Uint8 0 0 10 Predefined Number Send SMS To
8384 String Charger State 0 160 Predefined Number SMS Text
51820 Uint8 0 0 3 0 – None Priority Charger Current Bosch/Askoll
1 – Low
2 – High
3 – Panic
51823 Uint8 0 0 65535 mA Low Level
51822 Uint8 0 0 65535 mA High Level
51824 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51821 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7385 Uint8 0 0 10 Predefined Number Send SMS To
8385 String Charger Currrent 0 160 Predefined Number SMS Text
51830 Uint8 0 0 3 0 – None Priority Charger Control Mode Bosch
1 – Low
2 – High
3 – Panic
51833 Uint8 0 0 255 - Low Level
51832 Uint8 0 0 255 - High Level
51834 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51831 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7386 Uint8 0 0 10 Predefined Number Send SMS To
8386 String Charger Control Mode 0 160 Predefined Number SMS Text
51840 Uint8 0 0 3 0 – None Priority BMS COM Timeout Bosch
1 – Low
2 – High
3 – Panic
51843 Uint8 0 0 1 - Low Level
51842 Uint8 0 0 1 - High Level
51844 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51841 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7387 Uint8 0 0 10 Predefined Number Send SMS To
8387 String BMS COM Timeout 0 160 Predefined Number SMS Text
51850 Uint8 0 0 3 0 – None Priority Charger State Bosch
1 – Low
2 – High
3 – Panic
51853 Uint8 0 0 1 - Low Level
51852 Uint8 0 0 1 - High Level
51854 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51851 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7388 Uint8 0 0 10 Predefined Number Send SMS To
8388 String Charger CRC Violation 0 160 Predefined Number SMS Text
51860 Uint8 0 0 3 0 – None Priority Charger MC Violation Bosch
1 – Low
2 – High
3 – Panic
51863 Uint8 0 0 1 - Low Level
51862 Uint8 0 0 1 - High Level
51864 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51861 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7389 Uint8 0 0 10 Predefined Number Send SMS To
8389 String Charger MC Violation 0 160 Predefined Number SMS Text
51870 Uint8 0 0 3 0 – None Priority Charger Status Bosch
1 – Low
2 – High
3 – Panic
51873 Uint8 0 0 255 - Low Level
51872 Uint8 0 0 255 - High Level
51874 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51871 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7390 Uint8 0 0 10 Predefined Number Send SMS To
8390 String Charger Status 0 160 Predefined Number SMS Text
51880 Uint8 0 0 3 0 – None Priority Actual Voltage Bosch
1 – Low
2 – High
3 – Panic
51883 Uint8 0 0 65535 mV Low Level
51882 Uint8 0 0 65535 mV High Level
51884 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51881 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7391 Uint8 0 0 10 Predefined Number Send SMS To
8391 String Actual Voltage 0 160 Predefined Number SMS Text
51890 Uint8 0 0 3 0 – None Priority Charger Internal Fault Bosch
1 – Low
2 – High
3 – Panic
51893 Uint8 0 0 1 - Low Level
51892 Uint8 0 0 1 - High Level
51894 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51891 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7392 Uint8 0 0 10 Predefined Number Send SMS To
8392 String Charger Internal Fault 0 160 Predefined Number SMS Text
51900 Uint8 0 0 3 0 – None Priority Charger Energy Bosch
1 – Low
2 – High
3 – Panic
51903 Uint8 0 0 65535 Wh Low Level
51902 Uint8 0 0 65535 Wh High Level
51904 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51901 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7393 Uint8 0 0 10 Predefined Number Send SMS To
8393 String Charger Energy 0 160 Predefined Number SMS Text
51910 Uint8 0 0 3 0 – None Priority Actual Charger Current Bosch
1 – Low
2 – High
3 – Panic
51913 Uint8 0 0 65535 mA Low Level
51912 Uint8 0 0 65535 mA High Level
51914 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51911 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7394 Uint8 0 0 10 Predefined Number Send SMS To
8394 String Charger Current Actual 0 160 Predefined Number SMS Text
51920 Uint8 0 0 3 0 – None Priority Throttle Position Bosch/FLEX
1 – Low
2 – High
3 – Panic
51923 Uint8 0 0 100 % Low Level
51922 Uint8 0 0 100 % High Level
51924 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51921 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7395 Uint8 0 0 10 Predefined Number Send SMS To
8395 String Throttle Position 0 160 Predefined Number SMS Text
51930 Uint8 0 0 3 0 – None Priority Brake Pressed Bosch/FLEX
1 – Low
2 – High
3 – Panic
51933 Uint8 0 0 1 - Low Level
51932 Uint8 0 0 1 - High Level
51934 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51931 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7396 Uint8 0 0 10 Predefined Number Send SMS To
8396 String Brake Pressed 0 160 Predefined Number SMS Text
51940 Uint8 0 0 3 0 – None Priority Charger Plugged Bosch/FLEX
1 – Low
2 – High
3 – Panic
51943 Uint8 0 0 1 - Low Level
51942 Uint8 0 0 1 - High Level
51944 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51941 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7397 Uint8 0 0 10 Predefined Number Send SMS To
8397 String Charger Plugged 0 160 Predefined Number SMS Text
51950 Uint8 0 0 3 0 – None Priority Kill Switch Active Bosch/FLEX
1 – Low
2 – High
3 – Panic
51953 Uint8 0 0 0 - Low Level
51952 Uint8 0 0 1 - High Level
51954 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51951 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7398 Uint8 0 0 10 Predefined Number Send SMS To
8398 String Kill Switch Active 0 160 Predefined Number SMS Text
51960 Uint8 0 0 3 0 – None Priority Kickstand Realease Status Bosch/FLEX
1 – Low
2 – High
3 – Panic
51963 Uint8 0 0 0 - Low Level
51962 Uint8 0 0 1 - High Level
51964 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51961 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7399 Uint8 0 0 10 Predefined Number Send SMS To
8399 String Kickstand Release Status 0 160 Predefined Number SMS Text
51970 Uint8 0 0 3 0 – None Priority Powerstrain State Bosch/FLEX
1 – Low
2 – High
3 – Panic
51973 Uint8 0 0 7 - Low Level
51972 Uint8 0 0 7 - High Level
51974 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51971 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7400 Uint8 0 0 10 Predefined Number Send SMS To
8400 String Powertrain State 0 160 Predefined Number SMS Text
51980 Uint8 0 0 3 0 – None Priority Malfunction Indication Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
51983 Uint8 0 0 0 - Low Level
51982 Uint8 0 0 1 - High Level
51984 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51981 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7401 Uint8 0 0 10 Predefined Number Send SMS To
8401 String Malfunction Indication 0 160 Predefined Number SMS Text
51990 Uint8 0 0 3 0 – None Priority Estimated Range Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
51993 Uint8 0 0 65535 km Low Level
51992 Uint8 0 0 65535 km High Level
51994 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
51991 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7402 Uint8 0 0 10 Predefined Number Send SMS To
8402 String Estimated Range 0 160 Predefined Number SMS Text
52000 Uint8 0 0 3 0 – None Priority SoH Battery Bosch
1 – Low
2 – High
3 – Panic
52003 Uint8 0 0 100 % Low Level
52002 Uint8 0 0 100 % High Level
52004 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52001 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7403 Uint8 0 0 10 Predefined Number Send SMS To
8403 String SoH Battery 0 160 Predefined Number SMS Text
52010 Uint8 0 0 3 0 – None Priority SoC Battery Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
52013 Uint8 0 0 100 % Low Level
52012 Uint8 0 0 100 % High Level
52014 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52011 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7404 Uint8 0 0 10 Predefined Number Send SMS To
8404 String SoC Battery 0 160 Predefined Number SMS Text
52020 Uint8 0 0 3 0 – None Priority Vehicle Available Bosch
1 – Low
2 – High
3 – Panic
52023 Uint8 0 0 0 - Low Level
52022 Uint8 0 0 1 - High Level
52024 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52021 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7405 Uint8 0 0 10 Predefined Number Send SMS To
8405 String Vehicle Available 0 160 Predefined Number SMS Text
52030 Uint8 0 0 3 0 – None Priority Charging Active Bosch
1 – Low
2 – High
3 – Panic
52033 Uint8 0 0 0 - Low Level
52032 Uint8 0 0 1 - High Level
52034 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52031 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7406 Uint8 0 0 10 Predefined Number Send SMS To
8406 String Charging Active 0 160 Predefined Number SMS Text
52040 Uint8 0 0 3 0 – None Priority Remaining Charging Time Bosch
1 – Low
2 – High
3 – Panic
52043 Uint8 0 0 65535 Minutes Low Level
52042 Uint8 0 0 65535 Minutes High Level
52044 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52041 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7407 Uint8 0 0 10 Predefined Number Send SMS To
8407 String Remainign Charging Time 0 160 Predefined Number SMS Text
52050 Uint8 0 0 3 0 – None Priority Remaining Capacity Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
52053 Uint8 0 0 65535 Ah Low Level
52052 Uint8 0 0 65535 Ah High Level
52054 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7408 Uint8 0 0 10 Predefined Number Send SMS To
8408 String Remaining Capacity 0 160 Predefined Number SMS Text
52060 Uint8 0 0 3 0 – None Priority Full Charge Capacity Bosch/FLEX
1 – Low
2 – High
3 – Panic
52063 Uint8 0 0 65535 Ah Low Level
52062 Uint8 0 0 65535 Ah High Level
52064 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52061 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7409 Uint8 0 0 10 Predefined Number Send SMS To
8409 String Full Charge Capacity 0 160 Predefined Number SMS Text
52070 Uint8 0 0 3 0 – None Priority Driving Direction Bosch
1 – Low
2 – High
3 – Panic
52073 Uint8 0 0 3 - Low Level
52072 Uint8 0 0 3 - High Level
52074 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52071 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7410 Uint8 0 0 10 Predefined Number Send SMS To
8410 String Driving Direction 0 160 Predefined Number SMS Text
52080 Uint8 0 0 3 0 – None Priority Drive Mode Bosch/FLEX
1 – Low
2 – High
3 – Panic
52083 Uint8 0 0 3 - Low Level
52082 Uint8 0 0 3 - High Level
52084 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52081 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7411 Uint8 0 0 10 Predefined Number Send SMS To
8411 String Drive Mode 0 160 Predefined Number SMS Text
52090 Uint8 0 0 3 0 – None Priority Park Brake Active Bosch
1 – Low
2 – High
3 – Panic
52093 Uint8 0 0 0 - Low Level
52092 Uint8 0 0 1 - High Level
52094 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52091 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7412 Uint8 0 0 10 Predefined Number Send SMS To
8412 String Park brake Active 0 160 Predefined Number SMS Text
52100 Uint8 0 0 3 0 – None Priority Total Distance Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
52103 Uint8 0 0 1048573 km Low Level
52102 Uint8 0 0 1048573 km High Level
52104 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52101 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7413 Uint8 0 0 10 Predefined Number Send SMS To
8413 String Total Distance 0 160 Predefined Number SMS Text
52110 Uint8 0 0 3 0 – None Priority Total Distance Bosch/Askoll
1 – Low
2 – High
3 – Panic
52113 Uint8 0 0 4095000 km Low Level
52112 Uint8 0 0 4095000 km High Level
52114 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52111 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7414 Uint8 0 0 10 Predefined Number Send SMS To
8414 String Trip Distance 0 160 Predefined Number SMS Text
52120 Uint8 0 0 3 0 – None Priority Vehicle Speed Bosch/Askoll/FLEX
1 – Low
2 – High
3 – Panic
52123 Uint8 0 0 255 km/h Low Level
52122 Uint8 0 0 255 km/h High Level
52124 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52121 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7415 Uint8 0 0 10 Predefined Number Send SMS To
8415 String Vehicle Speed 0 160 Predefined Number SMS Text
52130 Uint8 0 0 3 0 – None Priority Ignition Status Bosch/FLEX
1 – Low
2 – High
3 – Panic
52133 Uint8 0 0 255 - Low Level
52132 Uint8 0 0 255 - High Level
52134 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52131 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7416 Uint8 0 0 10 Predefined Number Send SMS To
8416 String Ignition Status 0 160 Predefined Number SMS Text
52140 Uint8 0 0 3 0 – None Priority Ignition Fast Status Bosch/Askoll
1 – Low
2 – High
3 – Panic
52143 Uint8 0 0 7 - Low Level
52142 Uint8 0 0 7 - High Level
52144 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52141 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7417 Uint8 0 0 10 Predefined Number Send SMS To
8417 String Ignition Status 0 160 Predefined Number SMS Text
52150 Uint8 0 0 3 0 – None Priority Power Consumption Bosch
1 – Low
2 – High
3 – Panic
52153 Uint8 0 0 65535 Wh/km Low Level
52152 Uint8 0 0 65535 Wh/km High Level
52154 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52151 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7418 Uint8 0 0 10 Predefined Number Send SMS To
8418 String Power Consumption 0 160 Predefined Number SMS Text
54310 Uint8 0 0 3 0 – None Priority BMS0 Temperature Current Max Bosch
1 – Low
2 – High
3 – Panic
54313 Uint8 0 0 3 ‎°C Low Level
54312 Uint8 0 0 3 ‎°C High Level
54314 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54311 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7634 Uint8 0 0 10 Predefined Number Send SMS To
8634 String BMS0 Temperature Current Max 0 160 Predefined Number SMS Text
54320 Uint8 0 0 3 0 – None Priority BMS0 Temperature Current Min Bosch
1 – Low
2 – High
3 – Panic
54323 Uint8 0 0 3 ‎°C Low Level
54322 Uint8 0 0 3 ‎°C High Level
54324 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54321 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7635 Uint8 0 0 10 Predefined Number Send SMS To
8635 String BMS0 Temperature Current Min 0 160 Predefined Number SMS Text
54330 Uint8 0 0 3 0 – None Priority BMS0 Voltage Cell Min Bosch
1 – Low
2 – High
3 – Panic
54333 Uint8 0 0 3 ‎mV Low Level
54332 Uint8 0 0 3 ‎mV High Level
54334 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54331 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7636 Uint8 0 0 10 Predefined Number Send SMS To
8636 String BMS0 Voltage Cell Min 0 160 Predefined Number SMS Text
54340 Uint8 0 0 3 0 – None Priority BMS0 Voltage Cell Max Bosch
1 – Low
2 – High
3 – Panic
54343 Uint8 0 0 3 ‎mV Low Level
54342 Uint8 0 0 3 ‎mV High Level
54344 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54341 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7637 Uint8 0 0 10 Predefined Number Send SMS To
8637 String BMS0 Voltage Cell Max 0 160 Predefined Number SMS Text
54350 Uint8 0 0 3 0 – None Priority BMS1 Temperature Current Max Bosch
1 – Low
2 – High
3 – Panic
54353 Uint8 0 0 3 ‎°C Low Level
54352 Uint8 0 0 3 ‎°C High Level
54354 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54351 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7638 Uint8 0 0 10 Predefined Number Send SMS To
8638 String BMS1 Temperature Current Max 0 160 Predefined Number SMS Text
54360 Uint8 0 0 3 0 – None Priority BMS1 Temperature Current Min Bosch
1 – Low
2 – High
3 – Panic
54363 Uint8 0 0 3 ‎°C Low Level
54322 Uint8 0 0 3 ‎°C High Level
54364 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54361 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7639 Uint8 0 0 10 Predefined Number Send SMS To
8639 String BMS1 Temperature Current Min 0 160 Predefined Number SMS Text
54370 Uint8 0 0 3 0 – None Priority BMS1 Voltage Cell Min Bosch
1 – Low
2 – High
3 – Panic
54373 Uint8 0 0 3 ‎mV Low Level
54372 Uint8 0 0 3 ‎mV High Level
54374 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54371 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7640 Uint8 0 0 10 Predefined Number Send SMS To
8640 String BMS1 Voltage Cell Min 0 160 Predefined Number SMS Text
54380 Uint8 0 0 3 0 – None Priority BMS1 Voltage Cell Max Bosch
1 – Low
2 – High
3 – Panic
54383 Uint8 0 0 3 ‎mV Low Level
54382 Uint8 0 0 3 ‎mV High Level
54384 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54381 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7641 Uint8 0 0 10 Predefined Number Send SMS To
8641 String BMS1 Voltage Cell Max 0 160 Predefined Number SMS Text
52200 Uint8 0 0 3 0 – None Priority Helmet Status Askoll
1 – Low
2 – High
3 – Panic
52203 Uint8 0 0 0 - Low Level
52202 Uint8 0 0 1 - High Level
52204 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52201 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7423 Uint8 0 0 10 Predefined Number Send SMS To
8423 String Helmet Status 0 160 Predefined Number SMS Text
52210 Uint8 0 0 3 0 – None Priority Top Case Sensor Askoll/FLEX
1 – Low
2 – High
3 – Panic
52213 Uint8 0 0 0 - Low Level
52212 Uint8 0 0 1 - High Level
52214 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52211 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7424 Uint8 0 0 10 Predefined Number Send SMS To
8424 String Top case Sensor 0 160 Predefined Number SMS Text
52220 Uint8 0 0 3 0 – None Priority Central Standup Askoll
1 – Low
2 – High
3 – Panic
52223 Uint8 0 0 0 - Low Level
52222 Uint8 0 0 1 - High Level
52224 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52221 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7425 Uint8 0 0 10 Predefined Number Send SMS To
8425 String Central Standup 0 160 Predefined Number SMS Text
52230 Uint8 0 0 3 0 – None Priority Emergency Askoll
1 – Low
2 – High
3 – Panic
52233 Uint8 0 0 0 - Low Level
52232 Uint8 0 0 1 - High Level
52234 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52231 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7426 Uint8 0 0 10 Predefined Number Send SMS To
8426 String Emergency 0 160 Predefined Number SMS Text
52240 Uint8 0 0 3 0 – None Priority Over-Under Temperature Askoll
1 – Low
2 – High
3 – Panic
52243 Uint8 0 0 0 - Low Level
52242 Uint8 0 0 1 - High Level
52244 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52241 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7427 Uint8 0 0 10 Predefined Number Send SMS To
8427 String Over-Under Temperature 0 160 Predefined Number SMS Text
52250 Uint8 0 0 3 0 – None Priority Regeneration Disabled Askoll
1 – Low
2 – High
3 – Panic
52253 Uint8 0 0 0 - Low Level
52252 Uint8 0 0 1 - High Level
52254 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52251 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7428 Uint8 0 0 10 Predefined Number Send SMS To
8428 String Regeneration Disabled 0 160 Predefined Number SMS Text
52260 Uint8 0 0 3 0 – None Priority Battery on/off Askoll
1 – Low
2 – High
3 – Panic
52263 Uint8 0 0 0 - Low Level
52262 Uint8 0 0 1 - High Level
52264 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52261 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7429 Uint8 0 0 10 Predefined Number Send SMS To
8429 String Battery On/off 0 160 Predefined Number SMS Text
52270 Uint8 0 0 3 0 – None Priority Warning UnderVoltage Askoll
1 – Low
2 – High
3 – Panic
52273 Uint8 0 0 0 - Low Level
52272 Uint8 0 0 1 - High Level
52274 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52271 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7430 Uint8 0 0 10 Predefined Number Send SMS To
8430 String Warning UnderVoltage 0 160 Predefined Number SMS Text
52280 Uint8 0 0 3 0 – None Priority Warning OverVoltage Askoll
1 – Low
2 – High
3 – Panic
52283 Uint8 0 0 0 - Low Level
52282 Uint8 0 0 1 - High Level
52284 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52281 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7431 Uint8 0 0 10 Predefined Number Send SMS To
8431 String Warning OverVoltage 0 160 Predefined Number SMS Text
52290 Uint8 0 0 3 0 – None Priority Warning OverCurrent Askoll
1 – Low
2 – High
3 – Panic
52293 Uint8 0 0 0 - Low Level
52292 Uint8 0 0 1 - High Level
52294 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52291 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7432 Uint8 0 0 10 Predefined Number Send SMS To
8432 String Warning OverCurrent 0 160 Predefined Number SMS Text
52300 Uint8 0 0 3 0 – None Priority Warning Short Circuit Askoll
1 – Low
2 – High
3 – Panic
52303 Uint8 0 0 0 - Low Level
52302 Uint8 0 0 1 - High Level
52304 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
52301 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7433 Uint8 0 0 10 Predefined Number Send SMS To
8433 String Warning Short Circuit 0 160 Predefined Number SMS Text
54670 Uint8 0 0 3 0 – None Priority Max Available Power FLEX
1 – Low
2 – High
3 – Panic
54673 Uint8 0 0 0 W Low Level
54672 Uint8 0 0 36000 W High Level
54674 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54671 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7673 Uint8 0 0 10 Predefined Number Send SMS To
8673 String Max Available Power 0 160 Predefined Number SMS Text
54680 Uint8 0 0 3 0 – None Priority Handlebar Lock FLEX
1 – Low
2 – High
3 – Panic
54683 Uint8 0 0 0 - Low Level
54682 Uint8 0 0 1 - High Level
54684 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54681 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7674 Uint8 0 0 10 Predefined Number Send SMS To
8674 String Handlebar Lock 0 160 Predefined Number SMS Text
54690 Uint8 0 0 3 0 – None Priority Rear Brake Pressed FLEX
1 – Low
2 – High
3 – Panic
54693 Uint8 0 0 0 - Low Level
54692 Uint8 0 0 1 - High Level
54694 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54691 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7675 Uint8 0 0 10 Predefined Number Send SMS To
8675 String Rear Brake Pressed 0 160 Predefined Number SMS Text
54700 Uint8 0 0 3 0 – None Priority COM Error FLEX
1 – Low
2 – High
3 – Panic
54703 Uint8 0 0 0 - Low Level
54702 Uint8 0 0 1 - High Level
54704 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54701 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7676 Uint8 0 0 10 Predefined Number Send SMS To
8676 String COM Error 0 160 Predefined Number SMS Text
54710 Uint8 0 0 3 0 – None Priority RPM FLEX
1 – Low
2 – High
3 – Panic
54713 Uint8 0 0 0 rpm Low Level
54712 Uint8 0 0 1 rpm High Level
54714 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54711 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7677 Uint8 0 0 10 Predefined Number Send SMS To
8677 String RPM 0 160 Predefined Number SMS Text
54720 Uint8 0 0 3 0 – None Priority Torque Current FLEX
1 – Low
2 – High
3 – Panic
54723 Uint8 0 0 0 A Low Level
54722 Uint8 0 0 1 A High Level
54724 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54721 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7678 Uint8 0 0 10 Predefined Number Send SMS To
8678 String Torque Current 0 160 Predefined Number SMS Text
54520 Uint8 0 0 3 0 – None Priority Motor Temperature FLEX
1 – Low
2 – High
3 – Panic
54523 Uint8 0 0 0 °C Low Level
54522 Uint8 0 0 255 °C High Level
54524 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54521 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7657 Uint8 0 0 10 Predefined Number Send SMS To
8657 String Motor Temperature 0 160 Predefined Number SMS Text
54730 Uint8 0 0 3 0 – None Priority SN High FLEX
1 – Low
2 – High
3 – Panic
54734 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54731 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7679 Uint8 0 0 10 Predefined Number Send SMS To
8679 String SN High 0 160 Predefined Number SMS Text
54740 Uint8 0 0 3 0 – None Priority SN Low FLEX
1 – Low
2 – High
3 – Panic
54744 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54741 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7680 Uint8 0 0 10 Predefined Number Send SMS To
8680 String SN Low 0 160 Predefined Number SMS Text
54750 Uint8 0 0 3 0 – None Priority Lowest Battery Voltage FLEX
1 – Low
2 – High
3 – Panic
54753 Uint8 0 0 0 mV Low Level
54752 Uint8 0 0 65535 mV High Level
54754 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54751 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7681 Uint8 0 0 10 Predefined Number Send SMS To
8681 String Lowest Battery Voltage 0 160 Predefined Number SMS Text
54760 Uint8 0 0 3 0 – None Priority Lowest Battery ID FLEX
1 – Low
2 – High
3 – Panic
54764 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54761 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7682 Uint8 0 0 10 Predefined Number Send SMS To
8682 String Lowest Battery ID 0 160 Predefined Number SMS Text
54770 Uint8 0 0 3 0 – None Priority Highest Battery Voltage FLEX
1 – Low
2 – High
3 – Panic
54773 Uint8 0 0 0 mV Low Level
54772 Uint8 0 0 1 mV High Level
54774 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54771 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7683 Uint8 0 0 10 Predefined Number Send SMS To
8683 String Highest Battery Voltage 0 160 Predefined Number SMS Text
54780 Uint8 0 0 3 0 – None Priority Highest Battery ID FLEX
1 – Low
2 – High
3 – Panic
54784 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54781 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7684 Uint8 0 0 10 Predefined Number Send SMS To
8684 String Highest Battery ID 0 160 Predefined Number SMS Text
54790 Uint8 0 0 3 0 – None Priority Highest Mismatch Voltage FLEX
1 – Low
2 – High
3 – Panic
54793 Uint8 0 0 0 mV Low Level
54792 Uint8 0 0 65535 mV High Level
54794 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54791 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7685 Uint8 0 0 10 Predefined Number Send SMS To
8685 String Highest Mismatch Voltage 0 160 Predefined Number SMS Text
54800 Uint8 0 0 3 0 – None Priority Highest Mismatch ID FLEX
1 – Low
2 – High
3 – Panic
54804 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54801 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7686 Uint8 0 0 10 Predefined Number Send SMS To
8686 String Highest Mismatch ID 0 160 Predefined Number SMS Text
54810 Uint8 0 0 3 0 – None Priority Lowest Battery Temperature FLEX
1 – Low
2 – High
3 – Panic
54813 Uint8 0 0 0 °C Low Level
54812 Uint8 0 0 65535 °C High Level
54814 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54811 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7687 Uint8 0 0 10 Predefined Number Send SMS To
8687 String Lowest Battery Temperature 0 160 Predefined Number SMS Text
54820 Uint8 0 0 3 0 – None Priority Lowest Temperature Battery ID FLEX
1 – Low
2 – High
3 – Panic
54824 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54821 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7688 Uint8 0 0 10 Predefined Number Send SMS To
8688 String Lowest Temperature Battery ID 0 160 Predefined Number SMS Text
54830 Uint8 0 0 3 0 – None Priority Highest Battery Temperature FLEX
1 – Low
2 – High
3 – Panic
54833 Uint8 0 0 0 °C Low Level
54832 Uint8 0 0 65535 °C High Level
54834 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54831 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7689 Uint8 0 0 10 Predefined Number Send SMS To
8689 String Highest Battery Temperature 0 160 Predefined Number SMS Text
54840 Uint8 0 0 3 0 – None Priority Highest Temperature Battery ID FLEX
1 – Low
2 – High
3 – Panic
54844 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54841 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7690 Uint8 0 0 10 Predefined Number Send SMS To
8690 String Highest Temperature Battery ID 0 160 Predefined Number SMS Text
54850 Uint8 0 0 3 0 – None Priority Time To Full Load FLEX
1 – Low
2 – High
3 – Panic
54853 Uint8 0 0 0 s Low Level
54852 Uint8 0 0 65535 s High Level
54854 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54851 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7691 Uint8 0 0 10 Predefined Number Send SMS To
8691 String Time To Full Load 0 160 Predefined Number SMS Text
54860 Uint8 0 0 3 0 – None Priority Time To Empty FLEX
1 – Low
2 – High
3 – Panic
54863 Uint8 0 0 0 s Low Level
54862 Uint8 0 0 65535 s High Level
54864 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54861 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7692 Uint8 0 0 10 Predefined Number Send SMS To
8692 String Time To Empty 0 160 Predefined Number SMS Text
54870 Uint8 0 0 3 0 – None Priority Time To Full FLEX
1 – Low
2 – High
3 – Panic
54873 Uint8 0 0 0 s Low Level
54872 Uint8 0 0 65535 s High Level
54874 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54871 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7693 Uint8 0 0 10 Predefined Number Send SMS To
8693 String Time To Full 0 160 Predefined Number SMS Text
54880 Uint8 0 0 3 0 – None Priority Cluster State FLEX
1 – Low
2 – High
3 – Panic
54883 Uint8 0 0 0 - Low Level
54882 Uint8 0 0 5 - High Level
54884 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54881 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7694 Uint8 0 0 10 Predefined Number Send SMS To
8694 String Cluster State 0 160 Predefined Number SMS Text
54890 Uint8 0 0 3 0 – None Priority Cluster SoC FLEX
1 – Low
2 – High
3 – Panic
54893 Uint8 0 0 0 % Low Level
54892 Uint8 0 0 255 % High Level
54894 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54891 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7695 Uint8 0 0 10 Predefined Number Send SMS To
8695 String Cluster SoC 0 160 Predefined Number SMS Text
54900 Uint8 0 0 3 0 – None Priority Max Discharge Current FLEX
1 – Low
2 – High
3 – Panic
54903 Uint8 0 0 0 A Low Level
54902 Uint8 0 0 655353 A High Level
54904 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54901 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7696 Uint8 0 0 10 Predefined Number Send SMS To
8696 String Max Discharge Current 0 160 Predefined Number SMS Text
55220 Uint8 0 0 3 0 – None Priority Max Charge Current FLEX
1 – Low
2 – High
3 – Panic
55223 Uint8 0 0 0 A Low Level
55222 Uint8 0 0 65535 A High Level
55224 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55221 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7728 Uint8 0 0 10 Predefined Number Send SMS To
8728 String Max Charge Current 0 160 Predefined Number SMS Text
54910 Uint8 0 0 3 0 – None Priority Recuperation Allowed FLEX
1 – Low
2 – High
3 – Panic
54913 Uint8 0 0 0 - Low Level
54912 Uint8 0 0 1 - High Level
54914 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54911 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7697 Uint8 0 0 10 Predefined Number Send SMS To
8697 String Recuperation Allowed 0 160 Predefined Number SMS Text
54920 Uint8 0 0 3 0 – None Priority Switch Process Needed FLEX
1 – Low
2 – High
3 – Panic
54923 Uint8 0 0 0 - Low Level
54922 Uint8 0 0 1 - High Level
54924 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54921 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7698 Uint8 0 0 10 Predefined Number Send SMS To
8698 String Switch Process Needed 0 160 Predefined Number SMS Text
54930 Uint8 0 0 3 0 – None Priority SoC Switch Level FLEX
1 – Low
2 – High
3 – Panic
54933 Uint8 0 0 0 % Low Level
54932 Uint8 0 0 255 % High Level
54934 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54931 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7699 Uint8 0 0 10 Predefined Number Send SMS To
8699 String SoC Switch Level 0 160 Predefined Number SMS Text
54940 Uint8 0 0 3 0 – None Priority Part Charge Capacity FLEX
1 – Low
2 – High
3 – Panic
54943 Uint8 0 0 0 Ah Low Level
54942 Uint8 0 0 65535 Ah High Level
54944 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54941 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7700 Uint8 0 0 10 Predefined Number Send SMS To
8700 String Part Charge Capacity 0 160 Predefined Number SMS Text
54950 Uint8 0 0 3 0 – None Priority Cluster Voltage FLEX
1 – Low
2 – High
3 – Panic
54953 Uint8 0 0 0 V Low Level
54952 Uint8 0 0 65535 V High Level
54954 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54951 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7701 Uint8 0 0 10 Predefined Number Send SMS To
8701 String Cluster Voltage 0 160 Predefined Number SMS Text
54960 Uint8 0 0 3 0 – None Priority Cluster Current FLEX
1 – Low
2 – High
3 – Panic
54963 Uint8 0 0 0 A Low Level
54962 Uint8 0 0 65535 A High Level
54964 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54961 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7702 Uint8 0 0 10 Predefined Number Send SMS To
8702 String Cluster Current 0 160 Predefined Number SMS Text
54970 Uint8 0 0 3 0 – None Priority Major Version FLEX
1 – Low
2 – High
3 – Panic
54974 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54971 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7703 Uint8 0 0 10 Predefined Number Send SMS To
8703 String Major Version 0 160 Predefined Number SMS Text
54980 Uint8 0 0 3 0 – None Priority Minor Version FLEX
1 – Low
2 – High
3 – Panic
54984 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54981 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7704 Uint8 0 0 10 Predefined Number Send SMS To
8704 String Minor Version 0 160 Predefined Number SMS Text
54990 Uint8 0 0 3 0 – None Priority Patch Version FLEX
1 – Low
2 – High
3 – Panic
54994 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
54991 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7705 Uint8 0 0 10 Predefined Number Send SMS To
8705 String Patch Version 0 160 Predefined Number SMS Text
55000 Uint8 0 0 3 0 – None Priority Recognized Batteries FLEX
1 – Low
2 – High
3 – Panic
55003 Uint8 0 0 0 - Low Level
55002 Uint8 0 0 255 - High Level
55004 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55001 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7706 Uint8 0 0 10 Predefined Number Send SMS To
8706 String Recognized Batteries 0 160 Predefined Number SMS Text
55010 Uint8 0 0 3 0 – None Priority Activated Batteries FLEX
1 – Low
2 – High
3 – Panic
55013 Uint8 0 0 0 - Low Level
55012 Uint8 0 0 255 - High Level
55014 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55011 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7707 Uint8 0 0 10 Predefined Number Send SMS To
8707 String Activated Batteries 0 160 Predefined Number SMS Text
55020 Uint8 0 0 3 0 – None Priority Faulty Batteries FLEX
1 – Low
2 – High
3 – Panic
55023 Uint8 0 0 0 - Low Level
55022 Uint8 0 0 255 - High Level
55024 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55021 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7708 Uint8 0 0 10 Predefined Number Send SMS To
8708 String Faulty Batteries 0 160 Predefined Number SMS Text
55030 Uint8 0 0 3 0 – None Priority Battery 1 Voltage FLEX
1 – Low
2 – High
3 – Panic
55033 Uint8 0 0 65535 V Low Level
55032 Uint8 0 0 65535 V High Level
55034 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55031 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7709 Uint8 0 0 10 Predefined Number Send SMS To
8709 String Battery 1 Voltage 0 160 Predefined Number SMS Text
55040 Uint8 0 0 3 0 – None Priority Battery 1 Current FLEX
1 – Low
2 – High
3 – Panic
55043 Uint8 0 0 65535 A Low Level
55042 Uint8 0 0 65535 A High Level
55044 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55041 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7710 Uint8 0 0 10 Predefined Number Send SMS To
8710 String Battery 1 Current 0 160 Predefined Number SMS Text
55050 Uint8 0 0 3 0 – None Priority FLEX
1 – Low
2 – High
3 – Panic
55053 Uint8 0 0 65535 - Low Level
55052 Uint8 0 0 65535 - High Level
55054 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7711 Uint8 0 0 10 Predefined Number Send SMS To
8711 String Battery 1 State 0 160 Predefined Number SMS Text
55060 Uint8 0 0 3 0 – None Priority Battery 1 SoC FLEX
1 – Low
2 – High
3 – Panic
55063 Uint8 0 0 255 % Low Level
55062 Uint8 0 0 255 % High Level
55064 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55061 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7712 Uint8 0 0 10 Predefined Number Send SMS To
8712 String Battery 1 SoC 0 160 Predefined Number SMS Text
55070 Uint8 0 0 3 0 – None Priority Battery 1 Temperature 1 FLEX
1 – Low
2 – High
3 – Panic
55073 Uint8 0 0 127 °C Low Level
55072 Uint8 0 0 127 °C High Level
55074 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55071 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7713 Uint8 0 0 10 Predefined Number Send SMS To
8713 String Battery 1 Temperature 1 0 160 Predefined Number SMS Text
55080 Uint8 0 0 3 0 – None Priority Battery 1 Temperature 2 FLEX
1 – Low
2 – High
3 – Panic
55083 Uint8 0 0 127 °C Low Level
55082 Uint8 0 0 127 °C High Level
55084 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55081 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7714 Uint8 0 0 10 Predefined Number Send SMS To
8714 String Battery 1 Temperature 2 0 160 Predefined Number SMS Text
55090 Uint8 0 0 3 0 – None Priority Battery 1 Power Stage Temp FLEX
1 – Low
2 – High
3 – Panic
55093 Uint8 0 0 127 °C Low Level
55092 Uint8 0 0 127 °C High Level
55094 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55091 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7715 Uint8 0 0 10 Predefined Number Send SMS To
8715 String Battery 1 Power Stage Temp 0 160 Predefined Number SMS Text
55100 Uint8 0 0 3 0 – None Priority Battery 1 Remaining Capacity FLEX
1 – Low
2 – High
3 – Panic
55103 Uint8 0 0 65535 mAh Low Level
55102 Uint8 0 0 65535 mAh High Level
55104 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55101 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7716 Uint8 0 0 10 Predefined Number Send SMS To
8716 String Battery 1 Remaining Capacity 0 160 Predefined Number SMS Text
55110 Uint8 0 0 3 0 – None Priority Battery 2 Voltage FLEX
1 – Low
2 – High
3 – Panic
55113 Uint8 0 0 65535 V Low Level
55112 Uint8 0 0 65535 V High Level
55114 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55111 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7717 Uint8 0 0 10 Predefined Number Send SMS To
8717 String Battery 2 Voltage 0 160 Predefined Number SMS Text
55120 Uint8 0 0 3 0 – None Priority Battery 2 Current FLEX
1 – Low
2 – High
3 – Panic
55123 Uint8 0 0 65535 A Low Level
55122 Uint8 0 0 65335 A High Level
55124 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55121 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7718 Uint8 0 0 10 Predefined Number Send SMS To
8718 String Battery 2 Current 0 160 Predefined Number SMS Text
55130 Uint8 0 0 3 0 – None Priority Battery 2 State FLEX
1 – Low
2 – High
3 – Panic
55133 Uint8 0 0 65535 - Low Level
55132 Uint8 0 0 65535 - High Level
55134 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55131 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7719 Uint8 0 0 10 Predefined Number Send SMS To
8719 String Battery 2 State 0 160 Predefined Number SMS Text
55140 Uint8 0 0 3 0 – None Priority Battery 2 SoC FLEX
1 – Low
2 – High
3 – Panic
55143 Uint8 0 0 255 % Low Level
55142 Uint8 0 0 255 % High Level
55144 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55141 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7720 Uint8 0 0 10 Predefined Number Send SMS To
8720 String Battery 2 SoC 0 160 Predefined Number SMS Text
55150 Uint8 0 0 3 0 – None Priority Battery 2 Temperature 1 FLEX
1 – Low
2 – High
3 – Panic
55153 Uint8 0 0 127 °C Low Level
55152 Uint8 0 0 127 °C High Level
55154 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55151 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7721 Uint8 0 0 10 Predefined Number Send SMS To
8721 String Battery 2 Temperature 1 0 160 Predefined Number SMS Text
55160 Uint8 0 0 3 0 – None Priority Battery 2 Temperature 2 FLEX
1 – Low
2 – High
3 – Panic
55163 Uint8 0 0 127 °C Low Level
55162 Uint8 0 0 127 °C High Level
55164 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55161 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7722 Uint8 0 0 10 Predefined Number Send SMS To
8722 String Battery 2 Temperature 2 0 160 Predefined Number SMS Text
55170 Uint8 0 0 3 0 – None Priority Battery 2 Power Stage Temp FLEX
1 – Low
2 – High
3 – Panic
55173 Uint8 0 0 127 °C Low Level
55172 Uint8 0 0 127 °C High Level
55174 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55171 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7723 Uint8 0 0 10 Predefined Number Send SMS To
8723 String Battery 2 Power Stage Temp 0 160 Predefined Number SMS Text
55180 Uint8 0 0 3 0 – None Priority Battery 2 Remaining Capacity FLEX
1 – Low
2 – High
3 – Panic
55183 Uint8 0 0 65535 mAh Low Level
55182 Uint8 0 0 65535 mAh High Level
55184 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55181 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7724 Uint8 0 0 10 Predefined Number Send SMS To
8724 String Battery 2 Remaining Capacity 0 160 Predefined Number SMS Text
55190 Uint8 0 0 3 0 – None Priority Battery ID 0 Error Code FLEX
1 – Low
2 – High
3 – Panic
55194 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55191 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7725 Uint8 0 0 10 Predefined Number Send SMS To
8725 String Battery ID 0 Error Code 0 160 Predefined Number SMS Text
55200 Uint8 0 0 3 0 – None Priority Battery ID 1 Error Code FLEX
1 – Low
2 – High
3 – Panic
55204 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55201 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7726 Uint8 0 0 10 Predefined Number Send SMS To
8726 String Battery ID 1 Error Code 0 160 Predefined Number SMS Text
55210 Uint8 0 0 3 0 – None Priority Cluster Error Code FLEX
1 – Low
2 – High
3 – Panic
55214 Uint8 0 0 2 0 – No Event Only
1 – Yes
2 – Crash
55211 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7727 Uint8 0 0 10 Predefined Number Send SMS To
8727 String Cluster Error Code 0 160 Predefined Number SMS Text