Template:TMT250 Features Parameter list

From Wiki Knowledge Base | Teltonika Mobility

Alarm scenario parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11710 Uint8 0 0 1 0 – Disabled Scenario settings
1 – Enabled
11711 Uint8 0 0 1 0 – Disabled Call settings
1 – Enabled
11712 Uint8 0 0 10 Phone number Call to
7245 Uint8 0 0 10 Phone number Send SMS to
8245 String "Alarm" 0 160 Text Sms text

Overspeeding scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11104 Uint16 90 0 260 km/h Max speed
7032 Uint8 0 0 10 Phone number Send SMS to
8032 String "Overspeeding" 0 160 Text Sms text

ManDown scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12100 Uint8 0 0 1 0 – Disabled Scenario settings
1 – Enabled
12101 Uint8 1 0 1 0 – Horizontal Position
1 – Vertical
12102 Uint8 60 30 150 Degrees Angle
12103 Uint16 3 0 65500 Seconds Timeout
12104 Uint8 0 0 1 0 – Disabled Call settings
1 – Enabled
12105 Uint8 0 0 10 Phone number Call to
7222 Uint8 0 0 10 Phone number Send SMS to
8222 String "ManDown" 0 160 Text Sms text