1-Wire RFID reader

From Wiki Knowledge Base | Teltonika Mobility
Revision as of 13:52, 28 September 2021 by Ugnė D. (talk | contribs)

Accessories > 1-Wire RFID reader

Introduction to the product

Compatible with: | TFT100 |

RFID reader.jpg

One of the implemented features for fleet management devices is 1-Wire data protocol, which can be used to read RFID Tags by emulating them using iButton protocols. It is a convenient way to implement driver authorization in your vehicles if you want to use RFID Tags with minimal setup complexity.

1-Wire RFID readers are great in these use cases:

  • Immobilizer - prevent anyone from starting the vehicle without scanning an iButton first.

Technical characteristics

NAME DESCRIPTION
Interface 1-Wire Interface
Wiring White wire – 1-wire data, Brown wire – power supply, Green - ground.
Power Supply 6,5-30 V DC
Frequency standard 125 kHz
Type of transponder Manchester, 64 cycles per bit
Antenna surface area 6,8 cm²
Reading range 4 cm
Reading frequency 6 times per second for identification, 2 times per second when transponder is in range of reader
Supported 1-Wire commands 0x33 (0x0F) - Read ROM, 0xF0 - Search ROM
Fastening method M12 thread
Cable length 40 cm
Operating temperature -20 ºC to +55 ºC
Operating humidity Up to 70%

Installation

To connect the 1-wire RFID reader, simply connect the 1-Wire Signal wire from the reader to the 1-Wire Data pin on the device, connect the 1-Wire Power wire to the 1-Wire Power pin and connect the ground wire to the same grounding used for the device.

WIRE NAME of the TFT100 WIRE NAME of the SENSOR

DESCRIPTION

1-wire Data 1-wire Data Outputs identification data via 1-Wire interface
1-Wire Power VCC (+) Power supply for the sensor
GND GND (-) Ground

Device configuration

TFT100 iButton Read Notification.png

Since this reader emulates received RFID values as iButton values, it has identical functionality as the iButton reader in this regard. The reader works as soon as it is connected, but the iButton isn't used anywhere other than displayed in the iButton I/O element. In order to use it for the Immobilizer scenario, the device must have the scenario enabled. Then, iButton check can be enabled to only accept iButtons specified in the iButton list under the 1-Wire tab.

TFT100 1-Wire.png