TMT250 User interface
Indication is configurable in User Settings via configurator or via SMS/GPRS parameter ID. Indication works like this. Each 100 ms FW checks if any indication is enabled and triggered. If indication is triggered, then FW starts indicating. If other scenario wants to indicate on the same indication source, then it has to wait while active indication scenario finishes indicating. User can configure each indication like shown in the picture above. User can enable or disable indication, configure in which sleep mode indication can run, configure LED, Vibro, Period, Indication On, Off and how many times to repeat On/Off cycle. When period is set to 0, then indication will start immediately to indicate with configured LED and use vibration, if it is enabled. Period only works for scenarios that have type “Periodic”. Indication will turn on LED and Vibro for configured ON time, then turns off LED and Vibro and waits for configured OFF timeout. When Off timeout expires, then device checks into Repeat configuration, if it is higher then 0, then indication repeats On/Off cycle, if it is 0, then indication is finished. When indication is periodic and On parameter is set to 0, then LED and vibro will be set ON and will be set OFF only when indication will be canceled. Only Alarm and Power Key Pressed, Device Off indications can take over control of that LED and Vibro.
Name | Type | Trigger |
---|---|---|
GSM Error | Periodic | When SIM not inserted, is blocked, failed to connect to operator or jammed |
GSM Error | Periodic | When trying to register to GSM network |
GSM Error | One Off | When SMS is received or sent |
GSM Error | Periodic | When outgoing call is in process |
GSM Error | Periodic | When device is connected to server |
GSM Error | One Off | When eventual record is saved |
GSM Error | One Off | When panic record is saved |
GSM Error | Periodic | When device searches valid GPS fix |
GSM Error | Periodic | When device has valid GPS fix |
GSM Error | One Off | When device is turning off |
GSM Error | One Off | When device turns on |
GSM Error | Periodic | When alarm button is pressed and hold |
GSM Error | Periodic | When power button is pressed and hold |
GSM Error | One Off | Button was triggered with configured function to activate functionality |
GSM Error | One Off | Button was triggered with configured function to deactivate functionality |
GSM Error | Periodic | When device is charging |
GSM Error | Periodic | When device is fully charged |
GSM Error | Periodic | When ManDown functionality starts counting timeout til event |
GSM Error | Periodic | When device is in sleep mode |
GSM Error | Periodic | When configured period passes |